Sign In | Join Free | My himfr.com
Home > Pressure Temperature Transmitter >

STT850 Honeywell Pressure Transmitter , Pressure Indicator Transmitter 4-20 MA Dc

Shenzhen Wisdomlong Technology CO.,LTD
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap STT850 Honeywell Pressure Transmitter , Pressure Indicator Transmitter 4-20 MA Dc from wholesalers
     
    Buy cheap STT850 Honeywell Pressure Transmitter , Pressure Indicator Transmitter 4-20 MA Dc from wholesalers
    • Buy cheap STT850 Honeywell Pressure Transmitter , Pressure Indicator Transmitter 4-20 MA Dc from wholesalers
    • Buy cheap STT850 Honeywell Pressure Transmitter , Pressure Indicator Transmitter 4-20 MA Dc from wholesalers

    STT850 Honeywell Pressure Transmitter , Pressure Indicator Transmitter 4-20 MA Dc

    Ask Lasest Price
    Brand Name : Honeywell
    Model Number : STT850
    Price : negotiable
    Payment Terms : T/T
    Supply Ability : 100
    Delivery Time : 5-8 work days
    • Product Details
    • Company Profile

    STT850 Honeywell Pressure Transmitter , Pressure Indicator Transmitter 4-20 MA Dc

    Pressure Temperature Transmitter STT850 SmartLine Digital Accuracy up to +/- 0.10 Deg C for RTD 4-20 mA dc

    Introduction
    Part of the SmartLine® family of products, the SmartLine STT850 is a high-performance temperature transmitter offering high accuracy and stability over a wide range of process and ambient temperatures. The SmartLine family is also fully tested and compliant with Experion ® PKS providing the highest level of compatibility assurance and integration capabilities. SmartLine easily meets the most demanding needs for temperature measurement applications.


    Best in Class Features:

    Industry leading performance
    oDigital Accuracy up to +/- 0.10 Deg C for RTD
    o Stability up to +/- 0.01% of URL per year for ten years
    o 125 mSec update time for single input models
    o 250 mSec update time for dual input models

    Reliable measurement
    o Built in Galvanic Isolation
    o Differential/Averaging/Redundant/Split Range measurements
    o Dual Compartment Housing
    o Sensor Break detection
    o Comprehensive on-board diagnostic capabilities
    o Full compliance to SIL 2/3 requirements.
    o Available with 15 year warranty
    o Supports Namur 107 Extended Diagnostics
    o Supports Namur 89 Wire break
    o Direct entry of Callendar-Van Dusen coefficients R0, α, δ and β for calibrated RTD sensors (not
    available on DE units)

    Lower Cost of Ownership
    o Universal input
    o Dual sensor option
    o Multiple local display capabilities
    o Modular construction
    o External zero, span, & configuration capability
    o Polarity insensitive loop wiring
    o Digital Output Option (only available with HART)

    Communications/Output Options:
    o 4-20 mA dc
    o Honeywell Digitally Enhanced (DE)
    o HART ® (version 7.0)
    o FOUNDATION™ Fieldbus compliant to ITK 6.1.2 All transmitters are available with the above listed
    communications protocols.



    Instructions:
    Make selections from all Tables Key through XIII using column below the proper arrow. Asterisk indicates availability. Letter (a) refer to restrictions highlighted in the restrictions table. Tables delimited w ith dashes.


    Performance under Rated Conditions – All Models

    ParameterDescription
    Input Span Adjustment RangeNo limits to adjustments within the maximum range except minimum span limit of 1 engineering unit
    Analog Output Digital Communications:

    Two-wire, 4 to 20 mA (HART & DE Transmitters only)
    Honeywell DE, HART 7 protocol or FOUNDATION Fieldbus ITK 6.1.2 compliant All transmitters, irrespective of protocol have polarity insensitive connections.

    Output Failure Modes (HART/DE only)

    Honeywell Standard: NAMUR NE 43 Compliance:
    Normal Limits: 3.8 – 20.8 mA 3.8 – 20.5 mA
    Failure Mode: ≤ 3.6 mA and ≥ 21.0 mA ≤ 3.6 mA and ≥ 21.0 mA

    Output Accuracy (HART/DE only)±0.005 % span
    Supply Voltage Effect0.005 % span per volt.
    Transmitter Turn on Time (includes power up & test algorithms)HART or DE: 2.5 sec. Foundation Fieldbus: Host dependant
    Analog Input

    Stability: 0.01% of URL per Year for 10 years
    Maximum Lead Wire Resistance:
    Thermocouples: 50 ohms per leg
    RTD (all except Pt15) and Ohms: 50 ohms per leg
    RTD Pt25: 10 ohms per leg

    Response Time
    (delay + time constant)

    DE/HART Analog Output FOUNDATION Fieldbus
    Single Input: 130 - 230 mSec Host Dependant
    Dual Input: 305 - 455 mSec Host Dependant

    Update time

    125 mSec for single input units
    250 mSec for dual input units

    Damping Time Constant

    HART: Adjustable from 0 to 102 seconds in 0.1 increments. Default: 0.50 seconds
    DE: Discrete values 0.0, 0.3, 0.7, 1.5, 3.1, 6.3, 12.7, 25.5, 51.1, 102.3 seconds.
    Default: 0.3 seconds

    Ambient Temperature Effect

    Digital Accuracy
    For RTD Inputs: 0.0015 °C/°C
    For T/C Inputs: 0.005 °C/°C
    Output D/A: 0.0005 % of span/°C

    Cold Junction Accuracy±0.25 °C
    Total Reference Accuracy

    Digital Mode
    Digital Accuracy + C/J Accuracy (T/C input types only)
    Analog Mode (HART/DE only)
    Digital Accuracy + Output D/A Accuracy + C/J Accuracy (T/C input types only) Example: Transmitter in Analog Mode with Pt100 sensor and 0 to 200°C range Total Reference Accuracy = 0.10°C + (200 °C / 100 %) * 0.005 % = 0.11 °C

    Sensor BurnoutBurnout detection is user selectable. Upscale or down scale with critical status message. For RTD or ohm type inputs; broken wire/wires will be indicated
    Digital Output

    Contact Rating
    Voltage: +12 to +30 Vdc.
    Current: 40mA maximum (controlled by load resistance)
    Low Level: 0 to 2 Vdc

    Vibration EffectPer IEC60770-1 field or pipeline, high vibration level (10-2000Hz: 0.21 displacement/3g max acceleration)
    Electromagnetic CompatibilityIEC 61326-3-1
    Isolation2000 Vdc (1400Vrms) Galvanic isolation between inputs and output.
    Stray Rejection

    Common Mode
    AC (50 or 60 Hz): 120 dB (with maximum source impedance of 100 ohms) or ± 1 LSB (least significant bit) whichever is greater with line voltage applied.
    DC: 120 dB (with maximum source impedance of 50 ohms) or a ±1 LSB whichever is greater with 120 Vdc applied.
    DC (to 1 KHz): 50 dB (with maximum source of impedance of 50 ohms) or ±1 LSB whichever is greater with 50 Vac applied. Norma l Mode
    AC (50 or 60 Hz): 60 dB (with 100% span peak-to-peak maximum)

    EMC ComplianceEN 61326-1 and EN 61326-3-1 (SIL)
    Lightning Protection Option

    Leakage Current: 10 uA max @ 42.4 VDC 85 °C
    Impulse rating: 8/20 uS 5000 A (>10 strikes) 10000 A (1 strike min.)
    10/1000 uS 200 A (> 300 strikes)